Intravenous Regional Anesthesia (IVRA)



Figs. 33.1, 33.2, and 33.3
Areas of application of intravenous regional anesthesia





Specific Contraindications






  • Patient refusal


  • Local infection in the area to be anesthetized


  • Local nerve damage


  • Peripheral vascular diseases


  • Severe decompensated hypovolemia, shock


  • Certain cardiovascular diseases


  • Hypertonia, bradycardia, second-degree AV block, any history of a tendency to syncope


  • Musculoskeletal diseases


Procedure


This block should only be carried out when full anesthetic facilities are available. Full prior information for the patient is mandatory.


Preparations


Check that the appropriate emergency equipment is present and in working order. Sterile precautions. Two intravenous access points (in the healthy extremity as well as the one being operated on), BP and ECG monitoring, pulse oximetry, anesthesia machine. Patient preparation is the same as for general anesthesia.


Materials (Fig. 33.4)




A322756_4_En_33_Fig2_HTML.gif


Fig. 33.4
Materials

A 20- and 50-mL syringes, saline, cotton-wool padding, pneumatic tourniquet (double-lumen), Esmarch bandage, local anesthetic, disinfectant, pneumatic tourniquet device (e.g., VBM Medizintechnik Ltd., Sulz am Neckar, Germany; Fig. 33.5).

A322756_4_En_33_Fig3_HTML.gif


Fig. 33.5
Pneumatic tourniquet device (VBM Medizintechnik Ltd., Sulz am Neckar, Germany)


Patient Positioning


Supine, with the extremity free.


Technical Procedure




1.

Insert two intravenous catheters—one in a healthy extremity and the other as distally as possible in the extremity being operated on.

 

2.

Place the extremity being operated on in a free position and put soft padding under the tourniquet to help prevent nerve injury (Fig. 33.6).

A322756_4_En_33_Fig4_HTML.gif


Fig. 33.6
Padding of the tourniquet area, intravenous access

 

3.

Position the double-lumen tourniquet.

 

4.

Elevate and massage the limb for a few minutes and then wrap it completely with an Esmarch bandage (Fig. 33.7).

A322756_4_En_33_Fig5_HTML.gif


Fig. 33.7
Wrapping with an Esmarch bandage

 

5.

Inflate the proximal cuff: the pressure in the cuff has to be ca. 80–100 mmHg higher than the patient’s systolic blood pressure. The pressure that should be used depends on the thickness of the muscles being compressed. A pulse oximeter is used to document changes in, and cessation of, the pulse (“pulse occlusion pressure”) and the disappearance of the pulse in the radial artery. The “pulse occlusion pressure” can be used to determine the optimal pressure in the proximal cuff (Fig. 33.8).

A322756_4_En_33_Fig6_HTML.gif


Fig. 33.8
Inflation of the tourniquet

 

6.

Remove the bandage and place the extremity in a horizontal position.

 